[PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - BLADE SIGN DETAILS PAGE 4 - PENDING - 12-5-2025] BLADE SIGN ILLUM. - ELEVATION BLADE SIGN ILLUM. - SECTION Scale: 1 1/2" = 1’ - 0” Scale: 1” = 0’ - 2” | REMOTE LOCATION —— J Ruggles SIGN 93 Industry Drive PO Box 349 Versailles, KY 40383 859.879.1199 ADHERED 4 Alpha Slimline Series 12V-60W Power supply ASU-60-12U Abercrombie e & Fitch SIGN - DETAILS TOTAL - 6 SF 8'-0" MIN 6301 FITCH PATH eo = NEW ALBANY, OH 43054 /q\ 17/8” DIAMETER ALUMINUM PIPE PAINTED TO MATCH RAL 9005 - SATIN BLACK. ALUMINUM PIPE IS WELDED (1) To ALUMINUM MOUNTING PLATE. 1/8” THICK ROUTED ALUMINUM PANEL ROLLED AT TOP TO MOUNT FLUSH TO 1 7/8” DIAMETER PIPE. 1 7/8” X 1 7/8” ANGLED ALUMINUM WELDED TO INTERIOR SIDE OF PANEL. ALUMINUM PANEL IS MOUNTED TO PIPE WITH SCREWS THROUGH ANGLED ALUMINUM AND PIPE AND ADHESIVE ALONG TOP OF PIPE. ALUMINUM PANEL IS PAINTED TO MATCH RAL 9005 - SATIN BLACK. 1/8” THICK ROUTED ALUMINUM PANEL ROLLED AT TOP TO MOUNT FLUSH TO 1 7/8” DIAMETER PIPE. 11/2” X 11/2” ANGLES ALUMINUM WELDED TO INTERIOR SIDE OF PANEL. ALUMINUM PANEL IS MOUNTED TO PIPE WITH COUNTERSINK SCREWS ALONG TOP INTO PIPE AND ALONG BOTTOM THROUGH ANGLED ALUMINUM. ALUMINUM PANEL IS PAINTED TO MATCH RAL 9005 - SATIN BLACK. THIS PANEL IS REMOVABLE FOR SERVICING. 3/8” ALUMINUM MOUNTING PLATE, PAINTED TO MATCH RAL 9005 - SATIN BLACK. MOUNTED FLUSH TO WALL WITH APPROPRIATE FASTENERS FOR WALL CONDITIONS. PVC PIPE CAP, PAINTED TO MATCH ALUMINUM TUBE. 1/2” THICK WHITE 2447 ACRYLIC PUSH-THRU LETTERS MOUNTED TO ALUMINUM PANELS WITH STUDS AND FASTENED WITH NUTS ON THE INTERIOR SIDES. PRINCIPAL QWIK MODE 2 3500K LED UNITS MOUNTED AROUND WORDS TO ILLUMINATE LETTERS. HEYCO BUSHING FOR LOW VOLTAGE PASS-THRU TO BITRO ASU-60-12U LED DRIVER (120-277 VOLT) PLACED IN DRAIN HOLE WITH PAIGE 980054C SNAP 2 ENCLOSURE. LIGHT TENT DEDICATED PRIMARY SIGN CIRCUIT AND DISCONNECT PROVIDED BY ELECTRICIAN. AF BLD24 illum This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. TI includes proper grounding and bonding of the sign. RUGGLES SIGN DOES NOT PROVIDE PRIMARY ELECTRICAL TO SIGN LOCATION! Suitable for Wet Locations US UL label located on top of signs Submittal Date: ___12/10/21___ Acct Rep: ___ John Burns Designer: Fred Burch V REVISIONS 11:12/17/21 JB 7: _02/24/23 r2: 01/21/22 r§: 09/20/23 13: 04/05/22 JB 9: r4: 04/19/22 10: r5: 04/27/22 +11: r6: 05/13/22 12: PAGE: 4 --- [PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - MATERIALS AND FINISHES - PENDING - 12-5-2025] Abercrombie & Fitch Materials & Finishes / Crocker Park-Westlake OH/ 7 STOREFRONT SCONCES H480 Wall Sconce - Dual (Up & Down Lights) 168 MS Screw REMARKS. To tock the diffuser on the top Opal Acrylic Diffuser 1). LED Medules Options, Repicceatle LED é = Option.1, Power 6W, — Option.2, Power 6 Led Modules Dimmable p Li ke: | . ocation, Aluminum Lompsnode 2). Operetion to replece modules, Surface Finishing, Matte block Both Up & Down Modves cre fixed on the internal supporter, Modules con be replocecble by unlock the screws, DR LED Modules (Up & Down), PES See the Instruction sheet in addition to this shop drowing, ccT Exterior Store Front 3). Sw : rm (Prose Dim) . lace Finishing, Two Options (See Remorks) Motte Block Surfece 480 420 T Commector (Weterproof) To Combine Both Up & Ooen Modules into One input Mounting Box Surtoce Finishing, Matte Block ] —— H480 Metal Slat Wall Black Metal Signage — ; 7 228 ee 3/4" METAL SLAT; 3/4" EXTRUDED ALUMINUM ACM, 4MM PE, LARSON, CLASSIC BLACK, FIRE RAL2003 Signal White, MattelFifish se TUBING ON 1/8" THICK 6061 EXTRUDED RATING: FLAME SPREAD INDEX: 0, ASTM E84, series X. seats ALUMINUM BACKER 6" X 143" POWDER SMOKE DEVELOPMENT INDEX: 0, ASTM E84 / \ COATED GRECO (TIGER 038-68130) 140 125 0 | 168 t 228 TOR ViITw 180 VIEW exe. 0O08D Virw Finishes and materials may vary by region or store scope type, or be locally sourced by GC due to availability. --- [PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - SIGN DETAILS PAGE 4 - PENDING - 12-5-2025] FACE-LIT LETTERS ON RACEWAY - ELEVATION FACE-LIT LETTERS ON RACEWAY - SECTION Scale: 3/8” = 1’ - 0” TOTAL - 24.7SF Scale: 4” = 1’ - 0” IT | 1 6'-4" ‘* Abercrombie.& Fitch T Ruggles PO Box 349 Versailles, KY 40383 SIGN - DETAILS 859.879.1199 3” DEEP, ALUMINUM RETURNS WELDED TO 1/8” THICK ALUMINUM BACKS. ALL EXTERIOR SURFACES ARE PAINTED TO MATCH RAL-9005 BLACK, SATIN FINISH. ALL INTERIOR SURFACES ARE PAINTED HIGH GLOSS WHITE. (2) RETURNS AND BACK SEAM IS FULLY CAULKED TO ELIMINATE LIGHT LEAKS. 3/8” THICK 2447 WHITE ACRYLIC REVERSE PUSH-THRU LETTER FACES (1/8” EXPOSED) WITH FORWARD CUT DAY/NIGHT VINYL DIGITALLY Ab bi PRINTED TO MATCH RAL-9005 BLACK, SATIN FINISH APPLIED TO ACRYLIC FACE. ACRYLIC LETTERS SECURED TO RETURNS WITH 2-56 X 5/16” ercrombie COUNTERSUNK SCREWS. & Fitch (4) PRINCIPAL QWIK MODE 2 3500K WHITE LED UNITS TO ILLUMINATE LETTERS. 1” X 1” ALUMINUM TUBE ATTACHED TO BACK SIDE OF ‘I’ AND DOT OF ‘I’ WITH BOLTS, WASHERS AND NUTS. TUBE PAINTED TO MATCH CANOPY (T.B.D.). STORE: 11175 SPACE: Y2.120 2 1/2” TALL X 2 1/2” DEEP, CUSTOM RACEWAY PAINTED TO MATCH CANOPY (T.B.D.). SERVICE DOORS CUT ALONG TOP FOR INSTALLATION AND FUTURE SERVICING. RACEWAY WELDED TO 3” X 3” ALUMINUM ANGLE. DOMAIN NORTHSIDE 11821 ROCK ROSE AVE. (7) 3” X 3” ALUMINUM ANGLE PAINTED TO MATCH CANOPY (T.B.D.). AUSTIN, TX 78758 (8) HEYCO BUSHING FOR LOW VOLTAGE PASS-THRU TO BITRO LOW VOLTAGE LED DRIVER (120-277 VOLT) CONTAINED INSIDE RACEWAY. This sign is intended to be installed in accordance with the requirements of Article 600 (9) LETTERS BOTTOM MOUNT TO RACEWAY WITH RIV NUTS, ALL THREAD AND FASTENED WITH WIZ NUTS. of fe National Electrical code and/or other applicable local codes. This includes proper grounding and bonding of the sign. RUGGLES SIGN DOES NOT PROVIDE PRIMARY ELECTRICAL TO SIGN LOCATION! 10 RACEWAY MOUNTS FLUSH TO TOP OF CANOPY WITH SITE SPECIFIC FASTENERS (T.B.D.). ) DRAIN HOLE IN BOTTOM OF LETTER RETURN WITH LIGHT COVER. Suitable for (42) LED DRIVER CONNECTED TO DEDICATED PRIMARY SIGN CIRCUIT AND DISCONNECT SUPPLIED BY ELECTRICIAN. US Wet Locations Submittal Date: __01/27/25 _ Acct Rep: ___Maclain Evans __ Designer: ___ Fred Burch VV REVISIONS r1:__02/17/25 r2: r3: (10) E r4: r5: ré: LETTERS ARE FRONT ALIGNED WITH FRONT OF CANOPY AF25FL RPT DN BM RW --- [PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - SITE PLAN - PENDING - 12-5-2025] Abercrombie & Fitch Mall Plan / Crocker Park-Westlake OH/ 2 DSW Shoes = [ S$ Sandbox VR | 4 ST iN E 14,510« 6,335 www space Parking StueTOre bewarace Il ,plevels | = pide» | Parking Structure 4 levels Union Street Bath,ond Body s/'3,506+ “ Signed Leases. Leo's Italian Coming Soon Anthropologie? » Tf Social 10,000: Talbot's 7.5810 3 Warby Parker Tradehome Shoes 2,572sf 52 Fabletics Banana Republic 550% — Athleta 4 Hyde Park Ann Taylor Rally House 3.9851 13. Altard State 15,221 Outfitters Grille F , 6.139% own pact nen rs 45900 13,463 above 3" fs 7404" iC m-th 5.318:1ctow | White House 2.500sf «BlacksMarket * ce Apple - Now Open —,1 La iciecl image g.J America - H Now Open | ff ohare . Union Street wy [B]spaces --- [PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - STOREFRONT ELEVATION - PENDING - 12-5-2025] Abercrombie & Fitch ILLUMINATED SIGN ILLUMINATED BLADE SIGNS —i——) TUK] i Hh ‘ 0m DI ae pan N ( --- [PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - STOREFRONT ELEVATION FROM CORNER - PENDING - 12-5-2025] Storefront Rendering / Crocker Park-Westlake OH/ 6 Abercrombie & Fitch --- [PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - STOREFRONT ELEVATION FROM STREET - PENDING - 12-5-2025] Abercr ombie & F itch Storefront Rendering / Crocker Park-Westlake OH/ 5 in ell | Bal “fl WII --- [PLAN - Crocker Park Sign-Storefront Drawings for ABERCROMBIE FITCH -175 CROCKER PARK BOULEVARD - CALCULATION MATRIX - PENDING - 12-5-2025] ABERCROMBIE & FITCH - SIGNAGE MATRIX PRIMARY IDENTIFICATION SIGNS: Allowed 1 Primary |.D. Sign alg Actual Sign Area Fascla Sign rr Marquee ‘Canopy Sign a ee 24.7 af forva Sen piray) | Maximum Allowable Primary 97.5 sf 24.7 sf SECONDARY IDENTIFICATION SIGNS: Allowed 3 Secondary I.D. Signs Sign Tyr Actual Sign Area Projecting Blade Sign a Te 6 st x(2)= 128 porn Sgn coca) Plaque & Medallion Sign a eee Wo Dari ia Shed Bo ee Power ipa Cave Banner 50 af. 25 sf Flag eT eee Display Stand/Easel Maximum Alfowabia Secondary 48.75 +97,5 = 121.55 sf 52 sf Total Maximum Allowable Sign Area: =: 146.25 s! 76.7 sf --- [Abercrombie and Fitch Storefront and sign plan - Copy] WESTLAKE PLANNING COMMISSION STAFF REPORT 12/26/25 PART I GENERAL INFORMATION Abercrombie & Fitch sign plan and storefront, 175 Crocker Park Blvd., PP# 21124302, Ward 5 PART II PROJECT SUMMARY The purpose of this request is to remodel the former Arhaus store into two separate tenant spaces, accommodating (the subject of this report) and Hollister (also under consideration at this meeting). Abercrombie & Fitch will occupy the new tenant space fronting Crocker Park Boulevard, situated between the planned Hollister space and the pedestrian alley (a corner store). Storefront • The existing storefront facing Crocker Park Boulevard will be removed and replaced with: o Entry feature: Clad in aluminum composite material (ACM) in “Classic Black” finish to contrast with the main wall material. Metal canopy projecting 4’ feet from the wall, providing protection and a location for signage. Wall sconces in matching black aluminum flank the entry and provide accent lighting. o Storefront system: Black ACM panels above and below that aluminum storefront system that is in a matching color. o Main wall: Metal slat wall of extruded aluminum fine texture powder coating in flat matte tan color shown at right. • The existing storefront facing the alley remains unchanged, except for a small area that wraps the corner with the same metal slat wall material, terminating at the first window bay. • The proposed design complies with the Crocker Park Mixed Use Area Design Guidelines, which permit contemporary treatments. Sign Plan • A variety of signage types, including a canopy sign, two projecting blade signs, window decals and a banner sign to advertise the business and enhance the visual interest of the storefront. • Canopy sign (24.7 SF): 18” high, face-lit interior illuminated channel letters on raceway with white acrylic faces overlayed in vinyl for black day color and white night color. All other materials of aluminum in black satin finish to match the canopy. • Projecting blade sign (2 x 6 SF = 12 SF): aluminum face blade sign in satin black to match canopy sign and entry features, featuring push-thru illuminated acrylic letters in white. • Window decal - front elevation (8 x 1 SF = 8SF): 6.63” x 19.63” two per window bay and one on each door. Window decal - alley elevation (7 x 1 SF = Page 2 7SF): two per each of the three window bays, with an additional decal reserved for a future exit door installation. • Banner (25 SF): 2.5’ x 10’, projecting less than 42” from the wall and less than 50 SF total area. • Pursuant to the Crocker Park Master Sign Criteria Sections 3.1, 6.1, and 11.1, the proposed signs of such size, location and design are permitted and no waivers are necessary. • Moreover, the total sign area remains comfortably within the allowable limits, ensuring the tenant is not over-signed. PART III DEPARTMENTAL REVIEWS Fire 1. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters, Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7 mm). 2017 OFC Section 505.1 2. A Knox Box (approved locking key box) is required to be installed in an approved location determined by the Fire Department and 2017 OFC Section 506.1. Order the box at www.knoxbox.com. Minimum requirement for existing structures is the Surface Mount, Model 3261. For new construction the flushed mounted Recessed Box, Model 3270, plus the mounting kit Model 3290, is recommended. Contact the Westlake Fire Department at 440-835-6422 for more information or to determine the approved location. * may reuse exiting Knox box from the previous tenant if still installed at front entry PART IV DRAFT FINDINGS/MOTIONS Draft Findings of Fact 1. The contemporary storefront design with a new entry feature, canopy, accent lighting, and updated wall and storefront materials complies with the Crocker Park Mixed Use Area Design Guidelines. 2. Signage meets the Crocker Park Master Sign Criteria without requiring waivers. Draft Motions1 Storefront If the Planning Commission can make a recommendation, the following motion is advised: Based upon the findings of fact, I move to recommend approval of the Abercrombie and Fitch storefront with the condition that the Fire Department comments are addressed. Sign Plan If the Planning Commission can approve, the following motion is advised: Based upon the findings of fact, I move to approve the Abercrombie and Fitch sign plan. 1 This is suggested language only and not a recommendation for or against the approval of this request.